Engine Paralleling and Integration Control (EPIC)

Switchgear and Paralleling Controls

The Engine Paralleling and Integration Control (EPIC) product line provides standard paralleling controls in a remote cabinet separate from the engine generator set and separate from switchgear (breakers and bus).

Show
Configuration Remote modular paralleling control system (Master Control Panel for the first 2 generator sets and optional tie breaker, separate add-on control panels for up to 8 additional generator sets, utility paralleling control, and distribution control)
Modes of Operation Emergency Standby with redundant master control, Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel)
Application LV and MV (208V-27kV)
ANSI Protective Devices 15/25. 27/59, 81 O/U, 32, 40, 90 (Industrial Grade)

Availability Please Call Admin

OVERVIEW

The EPIC control system allows for modular application of paralleling controls. EPIC Master Panel provides a graphical interface to the generator sets, optional tie breaker, and optional Utility. Flexible control options allow for a variety of analog or high-speed network control of generators, making the EPIC system is an ideal choice for generation expansion projects whre there is need to parallel new generators with existing units.

FEATURES & BENEFITS

Product Features

Easy Connectivity to Generator Mounted Electrically Operated Circuit Breaker or Freestanding Switchgear with Electrically Operated BreakerHigh Speed Ethernet Supervisory... Read more

SPECIFICATIONS FOR Engine Paralleling and Integration Control (EPIC)

Collapse All
Technical Summary
Configuration Remote modular paralleling control system (Master Control Panel for the first 2 generator sets and optional tie breaker, separate add-on control panels for up to 8 additional generator sets, utility paralleling control, and distribution control)
Modes of Operation Emergency Standby with redundant master control, Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel)
Application LV and MV (208V-27kV)
Generator Protective Devices
ANSI Protective Devices 15/25. 27/59, 81 O/U, 32, 40, 90 (Industrial Grade)
Utility Protective Devices
ANSI Protective Devices 15/25. 27/59, 81 O/U, 32,47 (Industrial Grade)
Environmental Parameters
Certifications UL / cUL 508A
Control Panel Enclosure NEMA 12
Operating Temperature 0°C to 55°C
Storage Temperature -20°C to 60°C

SELECT MODELS TO COMPARE

Switchgear and Paralleling Controls

Cat Customizable Switchgear and Controls

Configuration Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc
Modes of Operation All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical power needs
Application LV and MV ( 208V - 38 kV) 50 / 60 Hz
ANSI Protective Devices Per customer specification
Switchgear and Paralleling Controls

Cat Switchgear

Configuration IP4X
Operating Temperature 35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths 600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.
Technical Summary Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers.
Switchgear and Paralleling Controls

Cat EGP Switchgear

Configuration Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications
Modes of Operation Multi-unit Island and multi-unit standby mode with optional redundant controls and components.
Application LV and MV (208V - 38 kV)
ANSI Protective Devices 15/25, 27/59, 81 O/U, 32, 40, 50, 51
Switchgear and Paralleling Controls

Cat XLM Switchgear

Configuration Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications
Modes of Operation Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power
Application LV and MV ( 208V - 38 kV
ANSI Protective Devices 15/25, 27/59, 81 O/U, 32, 40, 50, 51
Switchgear and Paralleling Controls

Cat Microgrid master Controller (MMC-M)

Configuration Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications
Modes of Operation Multi-unit Island and multi-unit standby mode with optional redundant controls and components.
Application LV and MV (208V - 38 kV)
ANSI Protective Devices 15/25, 27/59, 81 O/U, 32, 40, 50, 51
Switchgear and Paralleling Controls

Emergency Transfer Load Manager (EXL)

Configuration Wall mounted paralleling control system that monitors and controls a single generator and a single utility.
Modes of Operation Utility Import, Export, and base load operations, Peak shaving, and Emergency Standby. Closed Transition to/from Generator Power
Application LV and MV (208V-32kV)
ANSI Protective Devices 15/25. 27/59, 81 O/U, 32, 40, 50, 51
Switchgear and Paralleling Controls

Modular Switchgear fleXible (MSX) Range

Standard Widths 600 mm for MSX1600, MSX2000 and MSX2500; 750 mm for MSX3200, MSX4000 and MSX4000
Standard Heights Heights stated without removable plinth: 1800 mm for MSX1600, MSX2000, MSX2500, and MSX3200; 2250 mm for MSX4000 and MSX4000
Technical Summary Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers.
Standard Depths 900 mm
Switchgear and Paralleling Controls

PLC and SCADA Control Systems

Configuration IP4X
Operating Temperature 0 - 50 °C (32 - 122 °F)
Dimensions Depth 750 mm, Width 750 mm, Height 2200 mm
Application LV and MV
of

How to buy

VIEW ALL
01
SEND REQUEST

Select your equipment and fill out your contact information

02
GET A QUOTE

A sales rep will send you an official quote and other related information

03
PAYMENT & DELIVERY

Payment – Lead time - Delivery

Select Up to
3 Models to Compare
Model 1
Model 2
Model 3