Custom Switchgear and controls are design to provide a power generation, automation and distribution system specific to electrical needs.

Show
Configuration Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc
Modes of Operation All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical power needs
Application LV and MV ( 208V - 38 kV) 50 / 60 Hz
ANSI Protective Devices Per customer specification

Availability Please Call Admin

OVERVIEW

Caterpillar Customized Switchgear and Controls solutions enhance your ability to perfectly match your power generation capacity with the precise control your systems and process demand.

FEATURES & BENEFITS

XLM Switchgear

High Speed Supervisory Network Automatic Start/Stop Automatic “Dead Bus” Coordination Automatic Power Factor Control when in Parallel with Utility Power Programmable Loa... Read more

SPECIFICATIONS FOR Cat Customizable Switchgear and Controls

Collapse All
Technical Summary
Configuration Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc
Modes of Operation All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical power needs
Application LV and MV ( 208V - 38 kV) 50 / 60 Hz
Generator Protective Devices
ANSI Protective Devices Per customer specification
Utility Protective Devices
ANSI Protective Devices Per customer specification
Environmental Parameters
Certifications Per customer specification
Control Panel Enclosure Per customer specification
Operating Temperature Per customer specification
Storage Temperature Per customer specification
Low Voltage Standards Per customer specification
Medium Voltage Standards Per customer specification

SELECT MODELS TO COMPARE

Switchgear and Paralleling Controls

Engine Paralleling and Integration Control (EPIC)

Configuration Remote modular paralleling control system (Master Control Panel for the first 2 generator sets and optional tie breaker, separate add-on control panels for up to 8 additional generator sets, utility paralleling control, and distribution control)
Modes of Operation Emergency Standby with redundant master control, Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel)
Application LV and MV (208V-27kV)
ANSI Protective Devices 15/25. 27/59, 81 O/U, 32, 40, 90 (Industrial Grade)
Switchgear and Paralleling Controls

Cat XLM Switchgear

Configuration Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications
Modes of Operation Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power
Application LV and MV ( 208V - 38 kV
ANSI Protective Devices 15/25, 27/59, 81 O/U, 32, 40, 50, 51
Switchgear and Paralleling Controls

Cat Microgrid master Controller (MMC-M)

Configuration Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications
Modes of Operation Multi-unit Island and multi-unit standby mode with optional redundant controls and components.
Application LV and MV (208V - 38 kV)
ANSI Protective Devices 15/25, 27/59, 81 O/U, 32, 40, 50, 51
Switchgear and Paralleling Controls

EMCP 4.4 Master Control Panel

Configuration Remote monitoring and control for up to 8 generator sets via high-speed network. Enables paralleling a group of EMCP 4.4 equipped generator sets to a single utility source.
Modes of Operation Emergency standby, island, utility paralleling
Application LV and MV (208V - 38 kV)
ANSI Protective Devices 15/25, 27/59, 81 O/U, 32, 40, 50, 51
Switchgear and Paralleling Controls

Engine Generator Integrated Switchgear (EGIS)

Configuration Floor Standing modular switchgear paralleling system (Master Breaker Panel for the first 2 gensets, separate structures for up to 8 additional gensets , utility, and load control/distribution)
Modes of Operation Emergency Standby with redundant master control. Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel)
Application LV only (208V - 480V)
ANSI Protective Devices 15/25. 27/59, 81 O/U, 32, 40, 90 (Industrial Grade)
Switchgear and Paralleling Controls

Cat Switchgear

Configuration IP4X
Operating Temperature 35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths 600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.
Technical Summary Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers.
Switchgear and Paralleling Controls

PLC and SCADA Control Systems

Configuration IP4X
Operating Temperature 0 - 50 °C (32 - 122 °F)
Dimensions Depth 750 mm, Width 750 mm, Height 2200 mm
Application LV and MV
Switchgear and Paralleling Controls

Cat EGP Switchgear

Configuration Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications
Modes of Operation Multi-unit Island and multi-unit standby mode with optional redundant controls and components.
Application LV and MV (208V - 38 kV)
ANSI Protective Devices 15/25, 27/59, 81 O/U, 32, 40, 50, 51
of

How to buy

VIEW ALL
01
SEND REQUEST

Select your equipment and fill out your contact information

02
GET A QUOTE

A sales rep will send you an official quote and other related information

03
PAYMENT & DELIVERY

Payment – Lead time - Delivery

Select Up to
3 Models to Compare
Model 1
Model 2
Model 3