3516B (50 Hz) 2500 kVA with Upgradeable Package

Diesel Generator Sets

2000 - 2500 kVA at 50 Hz Diesel GensetThe 3516B generator set has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance that matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.Q. Does this generator comply with ISO 8528 guidelines?A. Yes, the 3516B, like all of our generators, is tested in accordnace the load steps outlined in with ISO 8528, Part 5.

Show
Standby Rating 2500 kVA
Prime Power Rating 2275 kVA
Emissions/Fuel Strategy Low Fuel, Low Emissions
Voltage 380 to 415 Volts

Availability Please Call Admin

OVERVIEW

Genset Diesel 2000 - 2500 kVA

FEATURES & BENEFITS

Cat Generator Set Package

Cat generator set packages have been fully prototype testedAccepts 100% block load in one step and meets NFPA 110 loading requirementsConform to ISO 8528-5 steady state a... Read more

Cat Diesel Engine

Reliable, rugged, durable designField-proven in thousands of applications worldwideFour-stroke-cycle diesel engine combines consistent performance and excellent fuel econ... Read more

SR5 Alternator

Superior motor starting capability minimizes need for oversizing alternatorDesigned to match performance and output characteristics of Cat diesel enginesRobust Class H in... Read more

EMCP 4 Control Panel

User-friendly interface and navigationScalable system to meet a wide range of installation requirementExpansion modules and site-specific programming for specific custome... Read more

Cooling System

Designed to operate in standard ambient temperatures up to 50°C (122°F)Contact your Cat Dealer for specific ambient and altitude capabilities Read more

Certifications

EU Declaration of ConformityEU Declaration of IncorporationEurasian ConformityTelecommunication Lab of China Read more

One Safe Source

Components used in the generator set are selected at the design stage to provide optimum package performanceThe generator set is fully assembled at a Caterpillar facility... Read more

World Wide Product Support

Cat dealers have over 1,800 dealer branch stores operating in 200 countriesYour local Cat dealer provides extensive post-sale support, including maintenance and repair ag... Read more

SPECIFICATIONS FOR 3516B (50 Hz) 2500 kVA with Upgradeable Package

Collapse All
Generator Set Specifications
Standby Rating 2500 kVA
Prime Power Rating 2275 kVA
Emissions/Fuel Strategy Low Fuel, Low Emissions
Voltage 380 to 415 Volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous
Maximum Rating 2500 kVA
Minimum Rating 2000 kVA
Engine Specifications
Engine Model 3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore 170 mm
Stroke 215 mm
Displacement 78 l
Compression Ratio 15.5:1
Aspiration TA
Fuel System Electronic unit injection
Governor Type Adem™3
Generator Set Dimensions
Length - Maximum 6282 mm
Width - Maximum 2286 mm
Height - Maximum 2494 mm
Dry Weight - Genset (maximum) 15535 kg

SELECT MODELS TO COMPARE

Diesel Generator Sets

3512 (50 Hz) with Upgradeable Package

Minimum Rating 1000 kVA
Maximum Rating 1400 kVA
Voltage 220 to 13800
Frequency 50 Hz
Diesel Generator Sets

C9 (60 Hz)

Maximum Rating 300 ekW
Minimum Rating 180 ekW
Emissions/Fuel Strategy EU Stage IIIA, Low Fuel
Voltage 220 to 480 Volts
Diesel Generator Sets

DE500 GC

Maximum Rating 500 kVA
Minimum Rating 500 kVA
Emissions/Fuel Strategy Non Regulated
Voltage 380 to 415 Volts
Diesel Generator Sets

C27 (60 Hz) Tier 4 Interim

Minimum Rating 725 ekW
Maximum Rating 800 ekW
Voltage 208 to 600
Frequency 60 Hz
Diesel Generator Sets

C32 (50 Hz) with Upgradeable Package

Minimum Rating 910 kVA
Maximum Rating 1500 kVA
Emissions/Fuel Strategy Low Fuel, Low Emissions
Voltage 400 to 415 Volts
Diesel Generator Sets

C175-20 (60 Hz)

Standby Rating 4000 (no fan)/3900/3620(no fan)/3500 ekW
Prime Power Rating 3600 (no fan)/3500/3300 (no fan)/3180 ekW
Emissions/Fuel Strategy Low Fuel, Tier 2
Voltage 480 to 13800 Volts
Diesel Generator Sets

CM43C Inline

Minimum Rating 5520 kWe
Maximum Rating 8290 kWe
Emissions/Fuel Strategy (WB) Cert stage 1 and 2
Voltage 3000 to 13800 Volts
Diesel Generator Sets

D500 GC (60 Hz)

Maximum Rating 500 ekW
Minimum Rating 500 ekW
Emissions/Fuel Strategy EPA Stationary Emergency
Voltage 480 to 600 Volts
of

How to buy

VIEW ALL
01
SEND REQUEST

Select your equipment and fill out your contact information

02
GET A QUOTE

A sales rep will send you an official quote and other related information

03
PAYMENT & DELIVERY

Payment – Lead time - Delivery

Select Up to
3 Models to Compare
Model 1
Model 2
Model 3