MENU
BUY PARTS
REQUEST QUOTE
FIND LOCATION
back
to top
Back to listing page

CM43C Inline

Diesel Generator Sets

Caterpillar electric power stands for reliable energy supply. Especially during the energy system transformation, Cat generator sets close the energy gap caused by renewable energy source such as wind and photo voltaic. Short ramp up time, low operating costs and rapid maintenance times ensures a high availability according to the need of our customers. Combined heat /cool and power solutions allow our customers to maximize the efficiency and earnings paired with low emissions. Wherever power is needed around the globe, Caterpillar is able to support you with the best products and services to maximize your profit.

Show
Minimum Rating 5520 kWe
Maximum Rating 8290 kWe
Emissions/Fuel Strategy (WB) Cert stage 1 and 2
Voltage 3000 to 13800 Volts

Availability Please Call Admin

OVERVIEW

CM43C Inline

FEATURES & BENEFITS

Reliable Operation

Intensive cooling of key components including exhaust valve seats, injector cooling integrated into lube oil systemReliable, proven and high efficient single turbo chargi... Read more

Control & Monitoring

Ultrafast start time and load acceptanceNo engine start limitationsContinuous power (base and peak load), prime power, stand-byPart load with high efficiencyMonitoring fo... Read more

Ease Of Installation

Reduced complexity of standard modular design allows an easy installationLow space requirements between the gensetsGenset is ready for installationGenerator set designed... Read more

Ease Of Operation

Low fuel and oil consumptionLow maintenance requirementsOperator and maintenance training courses available Read more

Intelligent Simplicity

High reliability, modular design and integral construction reduce the number of components by 40% over conventional designs e.g.:- Dry engine block with integrated ducts... Read more

Ease Of Maintenance

Smart maintenance solutions allow an easy component accessibilityLarge inspection openings afford an easy serviceability to core engine internalsCore engine components de... Read more

Fuel

Liquid: Light fuel oil (LFO), crude oil and heavy fuel oil (HFO) with fuel quality up to 700 cSt/50°C according to CIMAC H55/K55Dual:- Light fuel oil (LFO), crude oil and... Read more

Emissions

World bank emission certification (Stage 2)Technische Anleitung (TA) Luft (only gas)Post-emission treatment systems for lower emission requirements available Read more

Expertise & Experience

Assistance for planning - delivery - commissioning - operation and service)Expertise and experience for solutions to maximize benefits, e.g. combine heat and power system... Read more

SPECIFICATIONS FOR CM43C Inline

Collapse All
Generator Set Specifications
Minimum Rating 5520 kWe
Maximum Rating 8290 kWe
Emissions/Fuel Strategy (WB) Cert stage 1 and 2
Voltage 3000 to 13800 Volts
Frequency At Speed 50 Hz @ 500 / 60 Hz @ 514
Duty Cycle Prime, Continuous
Ready To Accept Loads (Preheated/Vented) 40 s
Normal Ramp Up To 100% Load 95 s
Emergency Ramp Up 10% To 100% Load 35 s
Genset Efficiency Up To 47.80%
Engine Specifications
Engine Model CM43C Inline, 4-stroke-engine
Bore 430 mm
Stroke 610 mm
Aspiration Turbocharged-aftercooled
Engine Rating Range 5640 - 8460 kW
Configuration 6,7,8,9 cylinder
Fuel Type Diesel oil / heavy fuel oil (HFO) / crude oil
Swept Volume 88.6 l/cyl
Mean Effective Pressure Up To 25.5 bar
Specific Fuel Oil Consumption (WB I) Up To 173 g/kWh
Specific Fuel Oil Consumption (WB II) Up To 174 g/kWh
Specific Lube Oil Consumption 0.35 g/kWh
Generator Set Dimensions
Length - Minimum 12202 mm
Length - Maximum 14459 mm
Width - Minimum 3400 mm
Width - Maximum 3400 mm
Height - Minimum 6278 mm
Height - Maximum 6649 mm
Dry Weight - Genset (minimum) 178 ton (US)
Dry Weight - Genset (maximum) 240 ton (US)

SELECT MODELS TO COMPARE

Diesel Generator Sets

C18 (60 Hz)

Maximum Rating 600 ekW
Minimum Rating 455 ekW
Emissions/Fuel Strategy U.S. EPA Cert., Tier 2
Voltage 208 to 600 Volts
Diesel Generator Sets

D350 GC

Minimum Rating 350 ekW
Maximum Rating 400 ekW
Emissions/Fuel Strategy EPA Stationary Emerg Use
Voltage 480 to 600 Volts
Diesel Generator Sets

3516B (60 Hz)

Minimum Rating 1640 ekW
Maximum Rating 2250 ekW
Voltage 220 to 13800
Frequency 60 Hz
Diesel Generator Sets

C18 (60 Hz)

Maximum Rating 600 ekW
Minimum Rating 455 ekW
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 208 to 600 Volts
Diesel Generator Sets

C13 | 400 kVA (50 Hz)

Maximum Rating 400 kVA
Minimum Rating 400 kVA
Emissions/Fuel Strategy India CPCB/MoEF
Voltage 415 Volts
Diesel Generator Sets

C4.4 (60 Hz)

Maximum Rating 60 ekW
Minimum Rating 36 ekW
Emissions/Fuel Strategy U.S. EPA Cert., Tier 3
Voltage 208 to 600 Volts
Diesel Generator Sets

C2.2 | D20

Standby Rating 20.0 ekW
Frequency 60 Hz
Emissions/Fuel Strategy US EPA TIER 4I (EPA 40 CFR Part 1039 Interim Tier 4)
Voltage 480/277, 240/120, 208/120, 600/346, 240/120 VAC
Diesel Generator Sets

C13 (60 Hz)

Minimum Rating 320 ekW
Maximum Rating 400 ekW
Voltage 208 to 600 Volts
Frequency 60 Hz
of

How to buy

VIEW ALL
01
SEND REQUEST

Select your equipment and fill out your contact information

02
GET A QUOTE

A sales rep will send you an official quote and other related information

03
PAYMENT & DELIVERY

Payment – Lead time - Delivery

Select Up to
3 Models to Compare
Model 1
Model 2
Model 3